Show simple item record

dc.contributor.authorSambureni, Privilege
dc.date.accessioned2015-12-04T09:49:28Z
dc.date.available2015-12-04T09:49:28Z
dc.date.issued2015
dc.identifier.urihttp://hdl.handle.net/10394/15535
dc.descriptionMIng (Nuclear Engineering), North-West University, Potchefstroom Campus, 2015en_US
dc.description.abstractVery High Temperature Reactors are complex reactors and various system codes have been developed to design different aspects such as neutronics, thermal hydraulics etc. Flownex is one of the system codes and it has been used to model the flow and heat transfer for a pebble fuel element and pebble-bed reactor. Although Flownex has been used to model the High Temperature Test Reactor, the prismatic block was modelled in a simplified manner. The aim of this study was to develop a more integrated model for a single block. A one sixth block was modelled in Flownex and the results were validated by comparing the results with results obtained using the Computational Fluid Dynamics (CFD) code STAR-CCM+. The conduction heat transfer through the prismatic blocks containing the fuel elements in a Very High Temperature Reactor is of crucial importance for the proper operation of the reactor under normal operating conditions and upset conditions. In this study, a model developed in a system code, Flownex is discussed. The model comprised of a collection of 1-D solid conduction heat transfer, convection heat transfer and pipe elements that were arranged in such a manner to represent the heat transfer and fluid flow in the prismatic block using a network approach. The validity of the model was investigated by comparing the heat transfer and temperature distribution in the block for various scenarios with the corresponding values obtained using a detailed CFD model of one twelfth of a prismatic block. Cubical and triangular block verification cases were conducted in Flownex and the results were validated by STAR-CCM+. The results were very comparable; however one issue has to be addressed. The one sixth integrated prismatic block was then modelled for a steady state and the results were also comparable. The outlet helium temperatures predicted by the STAR-CCM+ model was 542.94 C, at the same time the Flownex model predicted 542.98 C. Although the Flownex model did not provide the same detail as the STAR-CCM+ model the agreement between the results obtained with the two codes was satisfactory. Based on these findings it was concluded that Flownex could be used to build a representative integrated network model for a prismatic block reactor.en_US
dc.language.isoenen_US
dc.subjectVHTRen_US
dc.subjectHTTRen_US
dc.subjectFlownexen_US
dc.subjectCFDen_US
dc.subjectSTAR-CCM+en_US
dc.titleThermal fluid network model for a prismatic block in a gas-cooled reactor using FLOWNEXen
dc.typeThesisen_US
dc.description.thesistypeMastersen_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record